Fiamma Elevata – Mod. EL
The flare consist of a burner installed at elevated position, equipped with a high-energy ignition Pilot and a flame detection system via Thermocouple. The combustion air is natural conveyed from the bottom part of flame shield and the combustion temperature will be max. di 800 °C .
The height of this flare are calculated according to the heat radiation released from burning to the ground and that will ensure an adeguate level of protection to peolple and equipments that are within range of the flare.
This type of Flare develops a luminous flame which extends beyond the top part, so the combustion temperature and emissions monitoring are difficult to control.
The ignition system is automatic type, operated by the electrical panel installed of the flare’s bottom side and initially involves the pilot’s ignition and subsequently the opening of the main Biogas valve.
The gas train and all accessories such as valves, flame arrestor, pressure gauge and other, are installed at ground level.
SITE UTILITIES
Power supply | Volt | 400 |
Auxiliary circuits Power | Volt | 230-24 |
Frequency | Hz | 50 |
Electrical Insulation (Local Panel) | Gr. | IP54 |
Electrical Protection (Field equipments) | Gr. | IP65 |
Instrument Air Type | / | Dry, without oil |
Instrument Air Dew point | °C | -25 |
Instrument Air ( Wet, without Oil) | barg | 6 |
DESIGN CODES
73/23/CE et 93/68/CE
EN 60439-1
98/37/CE
EN 746-2
94/9 CE ATEX
SUPPLIER DATA
Model | EL | |
Type | Elevated Flame | |
Total Height (from ground) | m | 4 > 12 |
Type of support | Selfstanding | |
Gas Pipe Material | AISI 304 | |
Wind Shield | AISI 304/309 | |
Burner Material | AISI 316/310 | |
Air Damper Material | N.A. | |
Inlet Flange | ANSI B16.5 – 150# | |
Flame Detector | Thermocouple Typ. K | |
Internal Insulation | N.A. | |
External Insulation (Only in the Top parts lg. 1 ml.) | N.A. |